Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53.582
Filtrar
1.
BMC Cancer ; 24(1): 437, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594603

RESUMO

BACKGROUND: Soft tissue sarcomas (STS), have significant inter- and intra-tumoral heterogeneity, with poor response to standard neoadjuvant radiotherapy (RT). Achieving a favorable pathologic response (FPR ≥ 95%) from RT is associated with improved patient outcome. Genomic adjusted radiation dose (GARD), a radiation-specific metric that quantifies the expected RT treatment effect as a function of tumor dose and genomics, proposed that STS is significantly underdosed. STS have significant radiomic heterogeneity, where radiomic habitats can delineate regions of intra-tumoral hypoxia and radioresistance. We designed a novel clinical trial, Habitat Escalated Adaptive Therapy (HEAT), utilizing radiomic habitats to identify areas of radioresistance within the tumor and targeting them with GARD-optimized doses, to improve FPR in high-grade STS. METHODS: Phase 2 non-randomized single-arm clinical trial includes non-metastatic, resectable high-grade STS patients. Pre-treatment multiparametric MRIs (mpMRI) delineate three distinct intra-tumoral habitats based on apparent diffusion coefficient (ADC) and dynamic contrast enhanced (DCE) sequences. GARD estimates that simultaneous integrated boost (SIB) doses of 70 and 60 Gy in 25 fractions to the highest and intermediate radioresistant habitats, while the remaining volume receives standard 50 Gy, would lead to a > 3 fold FPR increase to 24%. Pre-treatment CT guided biopsies of each habitat along with clip placement will be performed for pathologic evaluation, future genomic studies, and response assessment. An mpMRI taken between weeks two and three of treatment will be used for biological plan adaptation to account for tumor response, in addition to an mpMRI after the completion of radiotherapy in addition to pathologic response, toxicity, radiomic response, disease control, and survival will be evaluated as secondary endpoints. Furthermore, liquid biopsy will be performed with mpMRI for future ancillary studies. DISCUSSION: This is the first clinical trial to test a novel genomic-based RT dose optimization (GARD) and to utilize radiomic habitats to identify and target radioresistance regions, as a strategy to improve the outcome of RT-treated STS patients. Its success could usher in a new phase in radiation oncology, integrating genomic and radiomic insights into clinical practice and trial designs, and may reveal new radiomic and genomic biomarkers, refining personalized treatment strategies for STS. TRIAL REGISTRATION: NCT05301283. TRIAL STATUS: The trial started recruitment on March 17, 2022.


Assuntos
Temperatura Alta , Sarcoma , Humanos , 60570 , Sarcoma/diagnóstico por imagem , Sarcoma/genética , Sarcoma/radioterapia , Genômica , Doses de Radiação
2.
J Am Heart Assoc ; 13(8): e033566, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38591342

RESUMO

BACKGROUND: Essential to a patient-centered approach to imaging individuals with chest pain is knowledge of differences in radiation effective dose across imaging modalities. Body mass index (BMI) is an important and underappreciated predictor of effective dose. This study evaluated the impact of BMI on estimated radiation exposure across imaging modalities. METHODS AND RESULTS: This was a retrospective analysis of patients with concern for cardiac ischemia undergoing positron emission tomography (PET)/computed tomography (CT), cadmium zinc telluride single-photon emission CT (SPECT) myocardial perfusion imaging, or coronary CT angiography (CCTA) using state-of-the-art imaging modalities and optimal radiation-sparing protocols. Radiation exposure was calculated across BMI categories based on established cardiac imaging-specific conversion factors. Among 9046 patients (mean±SD age, 64.3±13.1 years; 55% men; mean±SD BMI, 30.6±6.9 kg/m2), 4787 were imaged with PET/CT, 3092 were imaged with SPECT/CT, and 1167 were imaged with CCTA. Median (interquartile range) radiation effective doses were 4.4 (3.9-4.9) mSv for PET/CT, 4.9 (4.0-6.3) mSv for SPECT/CT, and 6.9 (4.0-11.2) mSv for CCTA. Patients at a BMI <20 kg/m2 had similar radiation effective dose with all 3 imaging modalities, whereas those with BMI ≥20 kg/m2 had the lowest effective dose with PET/CT. Radiation effective dose and variability increased dramatically with CCTA as BMI increased, and was 10 times higher in patients with BMI >45 kg/m2 compared with <20 kg/m2 (median, 26.9 versus 2.6 mSv). After multivariable adjustment, PET/CT offered the lowest effective dose, followed by SPECT/CT, and then CCTA (P<0.001). CONCLUSIONS: Although median radiation exposure is modest across state-of-the-art PET/CT, SPECT/CT, and CCTA systems using optimal radiation-sparing protocols, there are significant variations across modalities based on BMI. These data are important for making patient-centered decisions for ischemic testing.


Assuntos
Doença da Artéria Coronariana , Exposição à Radiação , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Índice de Massa Corporal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Dor no Peito , Angiografia Coronária/métodos
3.
Int J Mol Sci ; 25(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38612576

RESUMO

In a recent stereotactic body radiation therapy animal model, radiation pneumonitis and radiation pulmonary fibrosis were observed at around 2 and 6 weeks, respectively. However, the molecular signature of this model remains unclear. This study aimed to examine the molecular characteristics at these two stages using RNA-seq analysis. Transcriptomic profiling revealed distinct transcriptional patterns for each stage. Inflammatory response and immune cell activation were involved in both stages. Cell cycle processes and response to type II interferons were observed during the inflammation stage. Extracellular matrix organization and immunoglobulin production were noted during the fibrosis stage. To investigate the impact of a 10 Gy difference on fibrosis progression, doses of 45, 55, and 65 Gy were tested. A dose of 65 Gy was selected and compared with 75 Gy. The 65 Gy dose induced inflammation and fibrosis as well as the 75 Gy dose, but with reduced lung damage, fewer inflammatory cells, and decreased collagen deposition, particularly during the inflammation stage. Transcriptomic analysis revealed significant overlap, but differences were observed and clarified in Gene Ontology and KEGG pathway analysis, potentially influenced by changes in interferon-gamma-mediated lipid metabolism. This suggests the suitability of 65 Gy for future preclinical basic and pharmaceutical research connected with radiation-induced lung injury.


Assuntos
Lesão Pulmonar , Fibrose Pulmonar , Lesões por Radiação , Animais , Lesão Pulmonar/genética , Fibrose Pulmonar/genética , Inflamação , Interferon gama/genética , Pulmão , Doses de Radiação
4.
Eur Radiol Exp ; 8(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622388

RESUMO

BACKGROUND: Automatic exposure control (AEC) plays a crucial role in mammography by determining the exposure conditions needed to achieve specific image quality based on the absorption characteristics of compressed breasts. This study aimed to characterize the behavior of AEC for digital mammography (DM), digital breast tomosynthesis (DBT), and low-energy (LE) and high-energy (HE) acquisitions used in contrast-enhanced mammography (CEM) for three mammography systems from two manufacturers. METHODS: Using phantoms simulating various breast thicknesses, 363 studies were acquired using all available AEC modes 165 DM, 132 DBT, and 66 LE-CEM and HE-CEM. AEC behaviors were compared across systems and modalities to assess the impact of different technical components and manufacturers' strategies on the resulting mean glandular doses (MGDs) and image quality metrics such as contrast-to-noise ratio (CNR). RESULTS: For all systems and modalities, AEC increased MGD for increasing phantom thicknesses and decreased CNR. The median MGD values (interquartile ranges) were 1.135 mGy (0.772-1.668) for DM, 1.257 mGy (0.971-1.863) for DBT, 1.280 mGy (0.937-1.878) for LE-CEM, and 0.630 mGy (0.397-0.713) for HE-CEM. Medians CNRs were 14.2 (7.8-20.2) for DM, 4.91 (2.58-7.20) for a single projection in DBT, 11.9 (8.0-18.2) for LE-CEM, and 5.2 (3.6-9.2) for HE-CEM. AECs showed high repeatability, with variations lower than 5% for all modes in DM, DBT, and CEM. CONCLUSIONS: The study revealed substantial differences in AEC behavior between systems, modalities, and AEC modes, influenced by technical components and manufacturers' strategies, with potential implications in radiation dose and image quality in clinical settings. RELEVANCE STATEMENT: The study emphasized the central role of automatic exposure control in DM, DBT, and CEM acquisitions and the great variability in dose and image quality among manufacturers and between modalities. Caution is needed when generalizing conclusions about differences across mammography modalities. KEY POINTS: • AEC plays a crucial role in DM, DBT, and CEM. • AEC determines the "optimal" exposure conditions needed to achieve specific image quality. • The study revealed substantial differences in AEC behavior, influenced by differences in technical components and strategies.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Mamografia/métodos , Imagens de Fantasmas
5.
Sci Rep ; 14(1): 9475, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658572

RESUMO

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Assuntos
Osteotomia , Doses de Radiação , Exposição à Radiação , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto Jovem , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Luxação do Quadril/prevenção & controle , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Criança
6.
Sci Rep ; 14(1): 9358, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653758

RESUMO

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Assuntos
Fótons , Humanos , Tomografia Computadorizada por Raios X/métodos , Cadáver , Rotação , Doses de Radiação , Tomografia Computadorizada Espiral/métodos
7.
Sci Rep ; 14(1): 9373, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653993

RESUMO

To facilitate a prospective estimation of the effective dose of an CT scan prior to the actual scanning in order to use sophisticated patient risk minimizing methods, a prospective spatial dose estimation and the known anatomical structures are required. To this end, a CT reconstruction method is required to reconstruct CT volumes from as few projections as possible, i.e. by using the topograms, with anatomical structures as correct as possible. In this work, an optimized CT reconstruction model based on a generative adversarial network (GAN) is proposed. The GAN is trained to reconstruct 3D volumes from an anterior-posterior and a lateral CT projection. To enhance anatomical structures, a pre-trained organ segmentation network and the 3D perceptual loss are applied during the training phase, so that the model can then generate both organ-enhanced CT volume and organ segmentation masks. The proposed method can reconstruct CT volumes with PSNR of 26.49, RMSE of 196.17, and SSIM of 0.64, compared to 26.21, 201.55 and 0.63 using the baseline method. In terms of the anatomical structure, the proposed method effectively enhances the organ shapes and boundaries and allows for a straight-forward identification of the relevant anatomical structures. We note that conventional reconstruction metrics fail to indicate the enhancement of anatomical structures. In addition to such metrics, the evaluation is expanded with assessing the organ segmentation performance. The average organ dice of the proposed method is 0.71 compared with 0.63 for the baseline model, indicating the enhancement of anatomical structures.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Imagens de Fantasmas , Algoritmos , Estudos Prospectivos
8.
Health Phys ; 126(6): 386-396, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568156

RESUMO

ABSTRACT: The linear no-threshold (LNT) model has been the regulatory "law of the land" for decades. Despite the long-standing use of LNT, there is significant ongoing scientific disagreement on the applicability of LNT to low-dose radiation risk. A review of the low-dose risk literature of the last 10 y does not provide a clear answer, but rather the body of literature seems to be split between LNT, non-linear risk functions (e.g., supra- or sub-linear), and hormetic models. Furthermore, recent studies have started to explore whether radiation can play a role in the development of several non-cancer effects, such as heart disease, Parkinson's disease, and diabetes, the mechanisms of which are still being explored. Based on this review, there is insufficient evidence to replace LNT as the regulatory model despite the fact that it contributes to public radiophobia, unpreparedness in radiation emergency response, and extreme cleanup costs both following radiological or nuclear incidents and for routine decommissioning of nuclear power plants. Rather, additional research is needed to further understand the implications of low doses of radiation. The authors present an approach to meaningfully contribute to the science of low-dose research that incorporates machine learning and Edisonian approaches to data analysis.


Assuntos
Doses de Radiação , Humanos , Medição de Risco , Proteção Radiológica/normas , Relação Dose-Resposta à Radiação , Lesões por Radiação/prevenção & controle
9.
Health Phys ; 126(6): 374-385, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568154

RESUMO

ABSTRACT: The linear no-threshold (LNT) model may be useful as a simple basis for developing radiation protection regulations and standards, but it bears little resemblance to scientific reality and is probably overly conservative at low doses and low dose rates. This paper is an appeal for a broader view of radiation protection that involves more than just optimization of radiation dose. It is suggested that the LNT model should be replaced with a risk-informed, targeted approach to limitation of overall risks, which include radiation and other types of risks and accidents/incidents. The focus should be on protection of the individual. Limitation of overall risk does not necessarily always equate to minimization of individual or collective doses, but in some cases it might. Instead, risk assessment (hazards analysis) should be performed for each facility/and or specific job or operation (straightforward for specialized work such as radiography), and this should guide how limited resources are used to protect workers and the public. A graded approach could be used to prioritize the most significant risks and identify exposure scenarios that are unlikely or non-existent. The dose limits would then represent an acceptable level of risk, below which no further reduction in dose would be needed. Less resources should be spent on ALARA and tracking small individual and collective doses. Present dose limits are thought to be conservative and should suffice in general. Two exceptions are possibly the need for a lower (lifetime) dose limit for lens of the eye for astronauts and raising the public limit to 5 mSv y -1 from 1 mSv y -1 . This would harmonize the public limit with the current limit for the embryo fetus of the declared pregnant worker. Eight case studies are presented that emphasize how diverse and complex radiation risks can be, and in some cases, chemical and industrial risks outweigh radiation risks. More focus is needed on prevention of accidents and incidents involving a variety of types of risks. A targeted approach is needed, and commitments should be complied with until they are changed or exemptions are granted. No criticism of regulators or nuclear industry personnel is intended here. Protection of workers and the public is everyone's goal. The question is how best to accomplish that.


Assuntos
Proteção Radiológica , Humanos , Proteção Radiológica/normas , Proteção Radiológica/métodos , Medição de Risco/métodos , Doses de Radiação , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Modelos Lineares , Exposição à Radiação/prevenção & controle
10.
Health Phys ; 126(6): 397-404, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568172

RESUMO

ABSTRACT: Experiments that examine the impacts of subnatural background radiation exposure provide a unique approach to studying the biological effects of low-dose radiation. These experiments often need to be conducted in deep underground laboratories in order to filter surface-level cosmic radiation. This presents some logistical challenges in experimental design and necessitates a model organism with minimal maintenance. As such, desiccated yeast ( Saccharomyces cerevisiae ) is an ideal model system for these investigations. This study aimed to determine the impact of prolonged sub-background radiation exposure in anhydrobiotic (desiccated) yeast at SNOLAB in Sudbury, Ontario, Canada. Two yeast strains were used: a normal wild type and an isogenic recombinational repair-deficient rad51 knockout strain ( rad51 Δ). Desiccated yeast samples were stored in the normal background surface control laboratory (68.0 nGy h -1 ) and in the sub-background environment within SNOLAB (10.1 nGy h -1 ) for up to 48 wk. Post-rehydration survival, growth rate, and metabolic activity were assessed at multiple time points. Survival in the sub-background environment was significantly reduced by a factor of 1.39 and 2.67 in the wild type and rad51 ∆ strains, respectively. Post-rehydration metabolic activity measured via alamarBlue reduction remained unchanged in the wild type strain but was 26% lower in the sub-background rad51 ∆ strain. These results demonstrate that removing natural background radiation negatively impacts the survival and metabolism of desiccated yeast, highlighting the potential importance of natural radiation exposure in maintaining homeostasis of living organisms.


Assuntos
Dessecação , Saccharomyces cerevisiae , Saccharomyces cerevisiae/efeitos da radiação , Rad51 Recombinase/metabolismo , Exposição à Radiação/efeitos adversos , Exposição à Radiação/análise , Doses de Radiação
11.
Health Phys ; 126(6): 419-423, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568174

RESUMO

ABSTRACT: The system of radiological protection has been based on linear no-threshold theory and related dose-response models for health detriment (in part related to cancer induction) by ionizing radiation exposure for almost 70 y. The indicated system unintentionally promotes radiation phobia, which has harmed many in relationship to the Fukushima nuclear accident evacuations and led to some abortions following the Chernobyl nuclear accident. Linear no-threshold model users (mainly epidemiologists) imply that they can reliably assess the cancer excess relative risk (likely none) associated with tens or hundreds of nanogray (nGy) radiation doses to an organ (e.g., bone marrow); for 1,000 nGy, the excess relative risk is 1,000 times larger than that for 1 nGy. They are currently permitted this unscientific view (ignoring evolution-related natural defenses) because of the misinforming procedures used in data analyses of which many radiation experts are not aware. One such procedure is the intentional and unscientific vanishing of the excess relative risk uncertainty as radiation dose decreases toward assigned dose zero (for natural background radiation exposure). The main focus of this forum article is on correcting the serious error of discarding risk uncertainty and the impact of the correction. The result is that the last defense of the current system of radiological protection relying on linear no-threshold theory (i.e., epidemiologic studies implied findings of harm from very low doses) goes away. A revised system is therefore needed.


Assuntos
Proteção Radiológica , Humanos , Proteção Radiológica/normas , Medição de Risco , Doses de Radiação , Neoplasias Induzidas por Radiação/prevenção & controle , Neoplasias Induzidas por Radiação/etiologia , Exposição à Radiação/prevenção & controle , Exposição à Radiação/efeitos adversos , Relação Dose-Resposta à Radiação
13.
Radiología (Madr., Ed. impr.) ; 66(2): 107-113, Mar.- Abr. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-231512

RESUMO

Introducción y objetivos: Comparar las dosis de radiación en las gónadas con y sin protector gonadal y optimizar el uso de estos protectores al realizar radiografías de tórax a lactantes. Materiales y métodos: Se utilizan 2 maniquíes antropomórficos pediátricos, un sistema de rayos X KXO-50SS/DRX-3724HD, y un sistema de radiografía digital CALNEO Smart C12, con y sin protector de gónadas durante la realización de radiografías de tórax. Se coloca un dosímetro cutáneo en tiempo real en el sistema de rayos X y se inserta un dosímetro cutáneo en tiempo real en la cara anterior de la glándula mamaria, en la cara anterior y posterior de la pelvis verdadera, y en los ovarios y testículos. El sistema de rayos X se irradia 15 veces con maniquíes, con y sin el protector de gónadas. Se comparan los valores de las dosis de entrada del paciente medidos por el dosímetro cutáneo en tiempo real para cada maniquí, con y sin el protector de gónadas. Resultados: Los valores medios de las dosis a la entrada del paciente medidos para la cara anterior a nivel de la pelvis verdadera, con y sin el protector, son 10,00 y 5,00μGy en el recién nacido, y 10,00 y 0,00μGy al año, respectivamente. Los valores medios de las dosis a la entrada del paciente medidos para la cara posterior a nivel de la pelvis verdadera con y sin el protector son de 0,00 y 0,00μGy tanto en el recién nacido como al año, respectivamente. Las dosis a la entrada del paciente medidas no se pueden detectar en los ovarios y los testículos ni con el protector ni sin él. No se observan diferencias significativas en los valores de las dosis a la entrada del paciente medidas en la cara anterior y posterior de la pelvis, los ovarios y los testículos en el recién nacido y al año, con y sin el protector (p>0,05).(AU)


Introduction and objectives: To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. Materials and methods: Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. Results: The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00μGy at newborn, and 10.00 and 0.00μGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00μGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). Conclusions: No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.(AU)


Assuntos
Humanos , Masculino , Feminino , Lactente , Gônadas , Radiografia Torácica/métodos , Doses de Radiação , Raios X , Manequins , Radiologia , Radiografia Torácica/efeitos adversos
14.
Sci Rep ; 14(1): 6393, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493258

RESUMO

The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.


Assuntos
Tomografia Computadorizada por Raios X , Substância Branca , Humanos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Crânio/diagnóstico por imagem , Doses de Radiação
15.
Sci Rep ; 14(1): 7181, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531939

RESUMO

Ultra-low-dose computed tomography (ULD-CT) may combine the high sensitivity of conventional computed tomography (CT) in detecting sarcoma pulmonary metastasis, with a radiation dose in the same magnitude as chest X-ray (CXR). Fifty patients with non-metastatic high-grade soft tissue sarcoma treated with curative intention were recruited. Their follow-up involved both CXR and ULD-CT to evaluate their different sensitivity. Suspected findings were confirmed by conventional CT if necessary. Patients with isolated pulmonary metastases were treated with surgery or stereotactic body radiation therapy (SBRT) with curative intent if possible. The median effective dose from a single ULD-CT study was 0.27 mSv (range 0.12 to 0.89 mSv). Nine patients were diagnosed with asymptomatic lung metastases during the follow-up. Only three of them were visible in CXR and all nine in ULD-CT. CXR had therefore only a 33% sensitivity compared to ULD-CT. Four patients were operated, and one had SBRT to all pulmonary lesions. Eight of them, however, died of the disease. Two patients developed symptomatic metastatic recurrence involving extrapulmonary sites+/-the lungs between two imaging rounds. ULD-CT has higher sensitivity for the detection of sarcoma pulmonary metastasis than CXR, with a radiation dose considerably lower than conventional CT.Clinical trial registration: NCT05813808. 04-14-2023.


Assuntos
Neoplasias Pulmonares , Sarcoma , Humanos , Seguimentos , Neoplasias Pulmonares/secundário , Estudos Prospectivos , Doses de Radiação , Sarcoma/patologia , Tomografia Computadorizada por Raios X/métodos , Raios X
16.
Korean J Radiol ; 25(4): 384-394, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38528696

RESUMO

OBJECTIVE: To evaluate the image quality of novel dark-blood computed tomography angiography (CTA) imaging combined with deep learning reconstruction (DLR) compared to delayed-phase CTA images with hybrid iterative reconstruction (HIR), to visualize the cervical artery wall in patients with Takayasu arteritis (TAK). MATERIALS AND METHODS: This prospective study continuously recruited 53 patients with TAK (mean age: 33.8 ± 10.2 years; 49 females) between January and July 2022 who underwent head-neck CTA scans. The arterial- and delayed-phase images were reconstructed using HIR and DLR. Subtracted images of the arterial-phase from the delayed-phase were then added to the original delayed-phase using a denoising filter to generate the final-dark-blood images. Qualitative image quality scores and quantitative parameters were obtained and compared among the three groups of images: Delayed-HIR, Dark-blood-HIR, and Dark-blood-DLR. RESULTS: Compared to Delayed-HIR, Dark-blood-HIR images demonstrated higher qualitative scores in terms of vascular wall visualization and diagnostic confidence index (all P < 0.001). These qualitative scores further improved after applying DLR (Dark-blood-DLR compared to Dark-blood-HIR, all P < 0.001). Dark-blood DLR also showed higher scores for overall image noise than Dark-blood-HIR (P < 0.001). In the quantitative analysis, the contrast-to-noise ratio (CNR) values between the vessel wall and lumen for the bilateral common carotid arteries and brachiocephalic trunk were significantly higher on Dark-blood-HIR images than on Delayed-HIR images (all P < 0.05). The CNR values were significantly higher for Dark-blood-DLR than for Dark-blood-HIR in all cervical arteries (all P < 0.001). CONCLUSION: Compared with Delayed-HIR CTA, the dark-blood method combined with DLR improved CTA image quality and enhanced visualization of the cervical artery wall in patients with TAK.


Assuntos
Aprendizado Profundo , Arterite de Takayasu , Feminino , Humanos , Adulto Jovem , Adulto , Angiografia por Tomografia Computadorizada/métodos , Arterite de Takayasu/diagnóstico por imagem , Estudos Prospectivos , Artérias , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
17.
Radiol Clin North Am ; 62(3): 371-383, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553175

RESUMO

This review describes current state-of-the-art computed tomography technology required to address human-physiology-based challenges unique to angiographic imaging. Challenges are based on the need to image a bolus of contrast agent traversing inside rapidly moving structures. This article reviews the latest methods to optimize contrast timing and minimize motion.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
18.
Pediatr Radiol ; 54(4): 646-652, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472490

RESUMO

Hand-wrist radiography is the most common and accurate method for evaluating children's bone age. To reduce the scattered radiation of radiosensitive organs in bone age assessment, we designed a small X-ray instrument with radioprotection function by adding metal enclosure for X-ray shielding. We used a phantom operator to compare the scattered radiation doses received by sensitive organs under three different protection scenarios (proposed instrument, radiation personal protective equipment, no protection). The proposed instrument showed greater reduction in the mean dose of a single exposure compared with radiation personal protective equipment especially on the left side which was proximal to the X-ray machine (≥80.0% in eye and thyroid, ≥99.9% in breast and gonad). The proposed instrument provides a new pathway towards more convenient and efficient radioprotection.


Assuntos
Proteção Radiológica , Criança , Humanos , Doses de Radiação , Raios X , Radiografia , Proteção Radiológica/métodos , Fluoroscopia , Imagens de Fantasmas
19.
J Radiol Prot ; 44(2)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38507787

RESUMO

The manipulation of unsealed radiopharmaceuticals by healthcare workers can cause accidental personal contamination leading to occupational radiation skin dose. The UK Ionising Radiations Regulations 2017 require that potential skin doses arising from reasonably foreseeable accident scenarios are included in risk assessments. Workers must be designated as classified if these dose estimates exceed 150 mSv equivalent dose averaged over 1 cm2. Updates from the UK Health and Safety Executive recently prompted many in the UK to review the classification of workers in Nuclear Medicine. Skin dose from contamination cannot be measured, it must be estimated. Varskin+ is a code that is widely recommended for estimating skin dose. The subjective choices made by users when defining modelled scenarios in Varskin+ lead to significant variation in the calculated skin doses. At the time of writing there is no definitive calculation method and all calculations rely on theoretical models. NHS Health Boards in Scotland have adopted a standardised framework for performing skin dose estimates for risk assessments. The parametric sensitivity of Varskin+ inputs were examined and the available evidence was reviewed. Generic, reasonably forseeable, worst-case accident scenarios were decided upon for: direct skin contamination, glove contamination and needlestick injury. Standardised inputs and assumptions for each scenario were compiled in a protocol that has been adopted by the Scottish Health Boards. The protocol allows for differences in practice between departments, but standardises most inputs. While significant uncertainty remains in the estimated skin doses, this approach reduces variation and enables the comparison of estimated skin doses between departments. The framework facilitates continuous improvement as more evidence is gathered to refine the standardised assumptions. Task by task skin dose estimates were made for workers in Nuclear Medicine in Scotland and many workers were designated classified as a result.


Assuntos
Medicina Nuclear , Exposição Ocupacional , Humanos , Doses de Radiação , Radioisótopos , Pele , Compostos Radiofarmacêuticos
20.
Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38537310

RESUMO

Automated assessment of noise level in clinical computed tomography (CT) images is a crucial technique for evaluating and ensuring the quality of these images. There are various factors that can impact CT image noise, such as statistical noise, electronic noise, structure noise, texture noise, artifact noise, etc. In this study, a method was developed to measure the global noise index (GNI) in clinical CT scans due to the fluctuation of x-ray quanta. Initially, a noise map is generated by sliding a 10 × 10 pixel for calculating Hounsfield unit (HU) standard deviation and the noise map is further combined with the gradient magnitude map. By employing Boolean operation, pixels with high gradients are excluded from the noise histogram generated with the noise map. By comparing the shape of the noise histogram from this method with Christianson's tissue-type global noise measurement algorithm, it was observed that the noise histogram computed in anthropomorphic phantoms had a similar shape with a close GNI value. In patient CT images, excluding the HU deviation due the structure change demonstrated to have consistent GNI values across the entire CT scan range with high heterogeneous tissue compared to the GNI values using Christianson's tissue-type method. The proposed GNI was evaluated in phantom scans and was found to be capable of comparing scan protocols between different scanners. The variation of GNI when using different reconstruction kernels in clinical CT images demonstrated a similar relationship between noise level and kernel sharpness as observed in uniform phantom: sharper kernel resulted in noisier images. This indicated that GNI was a suitable index for estimating the noise level in clinical CT images with either a smooth or grainy appearance. The study's results suggested that the algorithm can be effectively utilized to screen the noise level for a better CT image quality control.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Controle de Qualidade , Artefatos , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...